# Osprey Demo ## Home - [Welcome to Osprey Support](https://support.ospreymeasurement.com/overview.md): Find guides, articles, and videos to help you get the best from Osprey products. ## OTS - [Osprey Tilt String (OTS)](https://support.ospreymeasurement.com/ots/overview.md): Compact, factory-assembled BUS of low power inclinometer sensors - [Equipment Preparation](https://support.ospreymeasurement.com/ots/user-guide/equipment-preparation.md): Prepare your OTS equipment for installation including mounting options, data logger setup, and initial checks - [Installation Guide](https://support.ospreymeasurement.com/ots/user-guide/installation.md): Step-by-step installation instructions for in-place inclinometer carriages - [Data Interpretation](https://support.ospreymeasurement.com/ots/user-guide/data-interpretation.md): Understanding Roll, Pitch, Yaw outputs and orientation measurements from OTS sensors ## ASP - [Automatic Settlement Profiler (ASP)](https://support.ospreymeasurement.com/asp/overview.md): Distributed settlement measurements along a nominally horizontal profile. hydrostatic principle - [Designing Your ASP Site](https://support.ospreymeasurement.com/layout.md): How to establish your settlement monitoring requirements and design an ASP that suits your site. - [Consider Site Conditions](https://support.ospreymeasurement.com/site-conditions.md): Consider the site conditions to ensure you get the most out of your settlement monitoring scheme. - [Establishing a Datum](https://support.ospreymeasurement.com/datum.md): All measurements are taken with reference to a datum - getting it right is essential! - [Order Your ASP](https://support.ospreymeasurement.com/order.md): Guide to ordering your ASP and accessories - [Pre-Installation Inspections](https://support.ospreymeasurement.com/asp/user-guide/inspection.md): Physical and operational checks to perform upon receiving your ASP system - [Establishing a Reference](https://support.ospreymeasurement.com/reference-pad.md): Complete installation instructions for ASP including reference pads, trench installation, and conduit methods - [Installing the ASP in a Trench](https://support.ospreymeasurement.com/installing-in-a-trench.md): No description found - [Installing in Conduit](https://support.ospreymeasurement.com/installing-in-a-conduit.md): No description found - [Connect the ASP](https://support.ospreymeasurement.com/asp/user-guide/connect.md): Wiring, protocols, and data conversion formulas for ASP system communication - [Data Reduction](https://support.ospreymeasurement.com/data-management.md): Convert ASP sensor outputs to relative or absolute settlement - [Campbell Scientific](https://support.ospreymeasurement.com/campbell-scientific.md): Logging the ASP with a Campbell Scientific Data Logger - [ASP Length Calculator](https://support.ospreymeasurement.com/asp/user-guide/asp-length-calculator.md): The ASP length calculator can be used to calculate the total length of your ASP - [Data Visualisation Tool for the ASP](https://support.ospreymeasurement.com/data-visualisation.md): The ASP Data Visualisation tools quickly and easily process ASP data. - [User Manual](https://support.ospreymeasurement.com/user-manual.md): Read or download the ASP user manual here. - [Standard Operating Procedure](https://support.ospreymeasurement.com/template-sops.md): SOP for installing and commissioning the ASP - [Inspection & Test Plan](https://support.ospreymeasurement.com/template-itps.md): ITPs for installation and commissioning of the ASP - [Compliance Certificates](https://support.ospreymeasurement.com/compliance-docs.md): Download certificates showing product compliance. - [MODBUS Reference](https://support.ospreymeasurement.com/asp/user-guide/modbus-reference.md): Complete MODBUS register map and status codes for ASP system - [Conduit vs Direct Burial](https://support.ospreymeasurement.com/conduit-vs-direct-burial.md): Which is best for your project? - [The Impact of Thermal Variation](https://support.ospreymeasurement.com/the-impact-of-temperature-variation.md): This article describes the impact temperature has on the ASP measurement performance, and how these can be mitigated. ## IPX - [In-Place Extensometer (IPX)](https://support.ospreymeasurement.com/ipx/overview.md): Magnetic-field sensitive probe for automated monitoring of magnetic extensometers - [Consider Site Conditions](https://support.ospreymeasurement.com/consider-site-conditions.md): Site conditions including geology and site activity will dictate the best - [Components](https://support.ospreymeasurement.com/components.md): Ancillary requirements and IPX equipment overview including access tubes, magnetic targets, and data logger compatibility - [Planning the Magnetic Extensometer Installation](https://support.ospreymeasurement.com/installing-the-magnetic-extensometer.md): No description found - [Installation Planning](https://support.ospreymeasurement.com/ipx/user-guide/installation-planning.md): Safety considerations, required tools and equipment, and planning guidelines for IPX installation - [Installation Execution](https://support.ospreymeasurement.com/ipx/user-guide/installation-execution.md): Installing the In-Place Extensometer (IPX) - [Initial Checks & Configuration](https://support.ospreymeasurement.com/ipx/user-guide/initial-checks.md): Physical inspection, functional testing, and configuration procedures for IPX sensors - [Data Management](https://support.ospreymeasurement.com/ipx/user-guide/data-management.md): Data logging, conversion formulas, and interpretation of IPX measurements - [Compliance Certificates](https://support.ospreymeasurement.com/compliance-certificates.md): Download certificates showing product compliance. - [MODBUS Reference](https://support.ospreymeasurement.com/ipx/user-guide/modbus-reference.md): Complete MODBUS RTU protocol specification and register maps for IPX system ## General - [General Products](https://support.ospreymeasurement.com/general/overview.md): Additional monitoring instruments and accessories - [De-Coiler](https://support.ospreymeasurement.com/de-coiler.md): Supports safe and easy de-coiling of cables, profilers and rapid-deploy systems - [USB to RS485 Interface](https://support.ospreymeasurement.com/usb-to-rs485-interface.md): Use an Android device and a USB to RS485 adapter to connect to OspreyBus sensors, configure serial settings, and send ASCII commands. - [Early Warning Indicators](https://support.ospreymeasurement.com/early-warning-indicators.md): No description found - [Using a Multimeter](https://support.ospreymeasurement.com/using-a-multimeter.md): No description found - [Modbus Reference](https://support.ospreymeasurement.com/modbus.md): No description found ## Applications - [Applications Overview](https://support.ospreymeasurement.com/applications/overview.md): Discover how Osprey measurement systems are used across diverse industries and infrastructure projects for reliable monitoring and data collection. - [Bridges](https://support.ospreymeasurement.com/applications/bridges.md): Monitor bridge behavior during construction and operation, focusing on settlement, rotation, and deck movement with Osprey instrumentation. - [Dams](https://support.ospreymeasurement.com/applications/dams.md): Monitor dam deformation, settlement, and structural behavior with Osprey instrumentation to verify design assumptions and support safe operation. - [Deep Excavation](https://support.ospreymeasurement.com/applications/deep-excavation.md): Monitoring considerations and relevant Osprey instrumentation for deep excavations. - [Earthworks](https://support.ospreymeasurement.com/applications/earthworks.md): Monitor earthworks settlement, deformation, and stability with Osprey instrumentation to verify design assumptions and protect nearby assets. - [Foundations](https://support.ospreymeasurement.com/applications/foundations.md): Monitor foundation settlement, heave, and tilt with Osprey instrumentation to verify design assumptions and protect nearby structures. - [Industrial](https://support.ospreymeasurement.com/applications/industrial.md): Monitoring ground and structural movement in industrial facilities using Osprey systems. - [Mines](https://support.ospreymeasurement.com/applications/mines.md): Deformation, settlement, and displacement monitoring in open-pit and underground mines using Osprey systems. - [Rail](https://support.ospreymeasurement.com/applications/rail.md): Application guide for using Osprey systems to monitor rail infrastructure. - [Slope Stability](https://support.ospreymeasurement.com/applications/slope-stability.md): How to use Osprey instrumentation to monitor slope stability, deformation, and settlement. - [Structures](https://support.ospreymeasurement.com/applications/structures.md): How to use Osprey monitoring systems on structural assets such as bridges, buildings, and civil infrastructure.